Premium 75 Ohm triple shielded coaxial cable for broadband networks HFC/CATV signal distribution. This cable is manufactured according highest quality standards and has PE gas injected dielectric with a stable impedance and fulfils in all aspects screening class A requirements. Applicable for indoor and outdoor use.
Available packages and colors:
5744 | High capacity digital coaxial cable RG-6, CCS, triple shielded, class A, white, 50m roll | IDLP-CRG6O5-CTWO50-RON |
5745 | High capacity digital coaxial cable RG-6, CCS, triple shielded, class A, black, 50m roll | IDLP-CRG6O5-CTBO50-RON |
5746 | High capacity digital coaxial cable RG-6, CCS, triple shielded, class A, white, 100m box | IDLP-CRG6O5-CTW100-BON |
5747 | High capacity digital coaxial cable RG-6, CCS, triple shielded, class A, black, 100m box | IDLP-CRG6O5-CTB100-BON |
5748 | High capacity digital coaxial cable RG-6, CCS, triple shielded, class A, white, 250m plastic reel | IDLP-CRG6O5-CTW250-REN |
5749 | High capacity digital coaxial cable RG-6, CCS, triple shielded, class A, black, 250m plastic reel | IDLP-CRG6O5-CTB250-REN |
5750 | High capacity digital coaxial cable RG-6, CCS, triple shielded, class A, white, 305m plastic reel | IDLP-CRG6O5-CTW305-REN |
5751 | High capacity digital coaxial cable RG-6, CCS, triple shielded, class A, black, 305m plastic reel | IDLP-CRG6O5-CTB305-REN |
Technical specifications | |
---|---|
Screening class | A |
Applicable |
indoor/outdoor |
|
|
Inner conductor |
|
Material |
CCS |
Diameter ᴓ [mm] |
1.02 |
Cladding conductivity [%] |
22 |
|
|
Dielectric |
|
Material |
PE gas injected |
Diameter ᴓ [mm] |
4.6 |
|
|
1st shielding |
|
Material |
Bonded Al/PET/Al |
Overlap [%] | 18 |
|
|
2nd shielding (braid) |
|
Material |
Al |
Braid coverage [%] |
65 |
|
|
3rd shielding |
|
Material |
Al/PET/Al foil |
|
|
Outer sheath |
|
Material |
PVC |
Sheath diameter ᴓ [mm] |
6.8 |
Sheath colour |
white or black |
RoHS complaint |
yes |
Characteristics |
UV protected, fire retardant, footage marker every meter |
|
|
Electrical data |
|
Impedance [Ω] |
75 ±2 |
Capacitance [pF/m] |
53 ±2 |
Velocity rate [%] |
83 |
DC resistance centre conductor [Ω/km] |
92 |
DC resistance outer conductor [Ω/km] |
24 |
Loop resistance [Ω/km] |
116 |
Sheath insulation voltage [kv] |
3 |
|
|
Attenuation [dB/100m] at 20⁰C @ |
|
5 MHz |
1.9 |
50 MHz |
4.9 |
100 MHz |
6.55 |
200 MHz |
10 |
300 MHz |
12 |
500 MHz |
15 |
800 MHz |
19 |
950 MHz |
21 |
1750 MHz |
29 |
2050 MHz |
31 |
2400 MHz |
33.7 |
3000 MHz |
37.5 |
|
|
Structural return loss [dB] @ |
|
5 MHz ~ 470 MHz |
> 26 |
> 470 MHz ~ 1000 MHz |
> 26 |
> 1000 MHz ~ 2000 MHz |
> 22 |
> 2000 MHz ~ 3000 MHz |
> 20 |
|
|
Screening attenuation [dB] @ |
|
30 MHz ~ 1000 MHz |
≥ 105 |
> 1000 MHz ~ 2000 MHz |
≥ 95 |
> 2000 MHz ~ 3000 MHz |
≥ 85 |
|
|
Transfer impedance [mΩ/m] @ |
|
10 MHz ~ 30 MHz |
≤ 5,0 |
|
|
Sweep tested @ |
|
5 MHz ~ 3000 MHz |
yes |
|
|
Mechanical data |
|
Operating temperature |
-30⁰C ~ +70⁰C |
Installation temperature |
-10⁰C ~ +50⁰C |
Bending radius (single/multiple) [mm] |
35/70 |
Tensile strength [N] |
120 |
Weight approx. [kg/km] |
42 |
Compliant according |
EN50117, IEC61196, Construction Product Regulations (CPR) |
Footage markers per meter |
1 |
Images